Process intensification is changing how biologics are manufactured, and continuous downstream processing is one of the main ways to achieve it. Continuous processing connects unit operations that have historically been run independently into a coordinated system that operates multiple steps in series simultaneously.

PAK BioSolutions and Cytiva have combined their systems to connect operations from capture through polishing. The ÄKTA pcc™ system runs continuous Protein A capture, and the PAK Pilot™ system runs viral inactivation, filtration, and polishing.

Cytiva logo
ÄKTA pcc system and PAK Pilot system

Defining Process Intensification in Downstream Processing

Process intensification focuses on improving how downstream processes are designed and operated. Its goal is to produce more product from the same equipment, footprint, and time, which lowers the cost of goods sold (COGS).

One way to achieve this is to cycle smaller columns and membrane adsorbers repeatedly, which reduces production costs by increasing resin and equipment utilization. When paired columns alternate between loading and regeneration, the feed never stops, and the process becomes continuous.

Continuous processing then allows operations such as chromatography, viral inactivation, and filtration to be connected into a single controlled process. This reduces intermediate holds and enables simultaneous operation of steps to reduce process time.

Batch vs. Continuous Downstream Processing

FeatureTraditional BatchContinuous Processing
WorkflowStep-by-stepIntegrated and simultaneous
Equipment useIdle between stepsContinuously utilized
Manual interventionHighReduced over 50%
FootprintLargerReduced

Structure of a Continuous Downstream Process

A continuous downstream process links multiple operations so material flows without interruption between steps.

PAK Pilot System flow diagram including virus inactivation, depth sterile filtration, and polishing chromatography

For a monoclonal antibody (mAb), the sequence of operations in a continuous downstream process typically starts like this:

  1. Affinity capture (Protein A). Protein A chromatography captures the antibody from the clarified harvest. A multi-column setup allows continuous loading: while one column loads, another is eluted and regenerated. The low-pH eluate then feeds directly into viral inactivation.
  2. Viral inactivation. The eluate is adjusted inline to a low pH, typically around 3.5. It then passes through a flow path sized to give a controlled residence time, which inactivates enveloped viruses without a hold tank.
  3. Product conditioning. The stream is then neutralized inline to the target pH. This protects product stability and sets the conditions needed for the next steps.
  4. Filtration. A filtration step then removes precipitates that form during viral inactivation. This protects the polishing columns from fouling and pressure buildup.
  5. Polishing chromatography. Finally, polishing chromatography removes remaining host cell protein (HCP), DNA, and viruses. It is often run in flow-through mode: impurities bind to the chromatography resin or membrane, while the product passes through.

Steps that were traditionally run separately, with holds between them, can now run continuously within one integrated system.


Automation Requirements for Continuous Processing

Continuous downstream processing depends on maintaining stable conditions across all unit operations.

Platforms such as the PAK Pilot system support:

  • Real-time flow balancing between unit operations
  • Automated diversion of out-of-spec material
  • Inline pH adjustment and conditioning
  • Surge vessel level control using PID logic
  • Continuous data capture for validation and traceability
Automated diversion of out-of-spec product
surge vessel flow control

In a continuous process, flow rate, pH, and residence time are interdependent process parameters. A change in flow rate, for example, alters both the residence time and the amount of acid or base needed for pH adjustment. PAK systems monitor all three parameters and adjust them in coordination. As a result, the process stays within specification, even over long run times.


Continuous Chromatography and ΔUV Control

Consistent column loading is a primary challenge in continuous chromatography. Feed concentration can drift over a long run, and column capacity can decline over repeated cycles. A fixed load volume may therefore underload a column in one cycle and overload it in the next.

Systems such as ÄKTA pcc address this with delta UV (ΔUV) control. UV detectors at the column inlet and outlet measure product breakthrough in real time, and the system switches columns when breakthrough reaches a set percentage. Loading therefore adjusts automatically to changes in feed concentration and column capacity.

The result is higher resin utilization, consistent product recovery, and stable multi-column operation.

ÄKTA pcc system delta UV consistent loading

Operational Advantages of an Integrated Continuous Platform

An integrated continuous platform shifts downstream processing from a sequence of discrete steps to a coordinated system. Multiple unit operations are synchronized within a single control framework, and automated process decisions reduce the need for operator intervention.

Because there are fewer transitions and hold steps between operations, process performance remains stable across extended run times.

Example: Integrated Continuous Downstream Platform

In work conducted with Cytiva, PAK BioSolutions combined chromatography and automation systems to control up to four unit operations simultaneously. Viral inactivation, filtration, and polishing were all performed in series.

The combined system supports a continuous downstream process suitable for clinical-scale manufacturing.


Where Continuous Processing Fits

Continuous downstream processing is most applicable when manufacturers are:

  • Scaling mAb production
  • Working within limited facility space
  • Improving consistency for GMP manufacturing
  • Need to reduce batch run time

Implementation Considerations

Continuous processing brings specific control challenges. The table below shows how integrated platforms address each one.

ChallengeApproach
Flow imbalancePID-based flow control with intermediate vessel monitoring
Product variabilityReal-time monitoring (ΔUV, pH, conductivity)
Process coordinationIntegrated automation architecture across steps
Process MonitoringContinuous data historization and trending tools

Adoption of Continuous Downstream Processing

Continuous downstream processing is being adopted more broadly as automation, monitoring, and system integration improve. Advances in control strategies and modular system design now support its use in development, pilot, and manufacturing environments.

 

Get access to the full technical poster “Process intensification: From unit operation to complete process,” best suited for professionals working in downstream processing, MSAT, and biopharma manufacturing.

    We respect your privacy and your time. Your information will never be sold. If you don't receive your download link via email within 10 minutes, please contact us.

    technical poster demonstrating how integrated automation and chromatography systems can accelerate the transition to fully continuous downstream biomanufacturing
    Automated diversion of out-of-spec product
    surge vessel flow control

    Cytiva and the Drop logo are trademarks of Global Life Sciences IP Holdings Corporation or an affiliate doing business as Cytiva. ÄKTA and ÄKTA pcc are trademarks of Global Life Sciences Solutions USA LLC or an affiliate doing business as Cytiva. PAK Pilot is a trademark of PAK BioSolutions Inc. Any other trademarks are the property of their respective owners.

    Recent Posts

    Explore Continuous Bioprocessing with PAK

    Interested in implementing continuous purification?

    • Evaluate system integration options
    • Request a demo of the PAK Pilot system
    • Speak with a process engineering expert

     

    Contact PAK BioSolutions