Commercial Scale Continuous Purification System
Automated end-to-end biopharmaceutical purification for cGMP manufacturing.
The PAK K-Series is designed for cGMP simultaneous operation of four sequential purification steps for monoclonal antibodies and other biopharmaceuticals.
A scale of 1,000 to 12,000+ L of cell culture per day makes the PAK K-Series the largest continuous processing system on the market.
The flow from one step to the next and the mass flow rate of the entire process is controlled with advanced automation, allowing for 24/7 hands-free operation.
Multiple skids can be connected in series to operate an entire downstream process continuously, with required instrumentation and buffer management seamlessly integrated.

Features:
- Automated sanitization, equilibration, steady state, and shutdown steps so you can focus on critical tasks.
- Single-use flow kit that includes all necessary connections, instrumentation, and sample ports.
- Automation that is 21 CFR Part 11 compliant and product contact materials of construction that meet USP Class VI.




Perform All Continuous Unit Operations Simultaneously
Run your process, your way. Select any order of unit operations with our PurSync Automation Control Package. Choose from the following:
Virus Inactivation
Virus inactivation steps are a critical component of biopharmaceutical purification processes. Continuous virus inactivation in the PAK system is achieved with inline pH adjustment or inline addition based on a volumetric ratio for detergent. Flow through a residence chamber provides the specified hold time to achieve the required virus log reduction values (LRV).
Additional highlights of the systems capabilities include:
- Continuous monitoring of pH and residence time to ensure out-of-spec material is not directed to the downstream purification stage.
- Inline pH, conductivity, or volumetric ratio buffer addition at the outlet of the virus inactivation step to meet target ranges for the subsequent stage.
Please contact us if you have questions or would like to ask us about our preferred inline virus inactivation method.
Flow-Through Filtration
Flow-through filtration steps include a 0.2 µm filter, depth filter, virus filter, or anion exchange membrane, among others. For these steps, the PAK System monitors the totalized process throughput, notifies the user when the membrane is nearing maximum capacity, and pauses the process if capacity is reached. Filters are often specified for once or twice daily replacement to not exceed capacities. The PAK system allows for inline buffer adjustments at the inlet and outlet of the step based on pH, conductivity or volumetric ratios. Back pressure control can also be performed with variable position pinch valves.
Dual Column Chromatography
A dual column chromatography step enables bind and elute chromatography to be performed in a semi-continuous manner. Two stages of the system can be configured to perform a dual column chromatography step. The first product pump of the two stages continuously feeds product intermediate from the upstream step onto one of the two columns where it binds to the resin. A sequence of buffers is flushed through the other column to remove impurities or elute product intermediate. After the buffer cycle is completed and the column in the load step has reached capacity, the two columns switch positions.
The system provides gradient capabilities as well as inline dilution to reduce buffer tank volumes. Two UV wavelengths can be monitored simultaneously, with a single wavelength and/or column volume set points used for elution collection criteria. The elution collection vessel is sized for at least five elution volumes and mixed to ensure material supplied to the next stage is consistent and does not result in a spike in product concentration, pH or conductivity during an elution step.
Inline Concentration
Concentration steps are performed with single pass tangential flow filtration (SPTFF).
With The PAK System, you can:
- Achieve your target concentration factor with a variable pinch valve for back pressure control.
- Calculate concentration factor based on flow rate ratios or monitor density with the single-use mass flow meter.
Diafiltration
A series of concentration and dilution steps, typically two or more, are performed in series to perform diafiltration or buffer exchange. A single PAK System can perform three concentration and dilution steps in series, followed by a final concentration step, to achieve the concentration and diafiltration targets of a traditional batch ultrafiltration/diafiltration (UFDF) process with greater than 99.75% buffer exchange.
New to continuous UFDF methods? Reach out to us if you would like assistance converting your traditional UFDF process to an inline concentration and diafiltration step.











Specifications
Hardware
Dimensions
- 82.5” W x 52” D x 65” H (system with nesting carts)
- 45” W x 30” D x 81” H (cabinet with touchscreen and keyboard)
Flow Rate Ranges
- 1.0 mL/min to 500 mL/min (low flow buffer pumps, qty. 2)
- 420 mL/min to 42 L/min (high flow buffer pumps, qty. 2)
- 333 mL/min to 20 L/min (product pumps, qty. 4)
Tubing Diameters Accepted 1/4″, 1/2”, 3/4”
Pressure Limit 4 bar (58 psi)
Equipment 4 buffer pumps, 4 product pumps, 24 pinch valves, and 20 buffer inlet valves
Automation
PurSync™ Automation Control Package
Synchronous operation of four sequential purification stages per system, and up to four systems in series.
- Control schemes for low pH viral inactivation, TFF for single pass concentration and diafiltration, viral and other filtration, and chromatography.
- Inline buffer adjustment based on pH, conductivity, or volumetric ratio on inlet and outlet of purification stages. Pressure control for each purification stage.
- Automated startup and shutdown, including priming, sanitization, equilibration, and storage.
Instrument
Pressure Sensors 4.1 bar (60 psi) maximum (qty. 8)
UV Sensors Any two specified wavelengths from 185 nm to 2600 nm (qty. 4)
pH Sensors 0 to 14 (qty. 8 max)*
Conductivity Sensors 0.02 mS/cm to 500 mS/cm (qty. 8 max)*
Scales Connections for six floor scales provided. Floor scales purchased separately.
Optional Mass flow meters or ultrasonic flow meters available.
*System includes eight transmitters that accept either pH or conductivity sensors. Any combination of these two sensor types may be installed, but the total quantity may not exceed eight.
Other
Electrical Requirements 480 V, 3-phase
Required Air Supply 6.2 bar (90 psi) instrument air
PLC Rockwell CompactLogix™ 5380
System Sizing
Purification of 1,000 L Cell Culture per Day (10,000 g mAb / day)¹
| Feature | Low pH VI | Filtration | Chromatography | UFDF |
|---|---|---|---|---|
| Product Flow Rate | ~200 mL/min | ~200 mL/min | ~200 mL/min | ~200 mL/min |
| Buffer Flow Rate | ~20 mL/min | n/a | 1.6 L/min | ~200 mL/min |
| Product Tubing Diameter | 1/2" | 1/2" | 1/2" | 1/2" |
| Buffer Tubing Diameter | 1/4" | n/a | 1/2" | 1/2" |
| Column/Filter Size | 30 cm diam column | ~0.4 m² replaced daily | 20 cm diam column | ~1.0 m² membrane |
| Vessel Volume | 5 L | 5 L | 200 L | 5 L |
Purification of 12,000 L Cell Culture per Day (60,000 g mAb / day)¹
| Feature | Low pH VI | Filtration | Chromatography | UFDF |
|---|---|---|---|---|
| Product Flow Rate | ~2 L/min | ~2 L/min | ~2 L/min | ~2 L/min |
| Buffer Flow Rate | ~200 mL/min | n/a | 14 L/min | ~2 L/min |
| Product Tubing Diameter | 3/4" | 3/4" | 3/4" | 3/4" |
| Buffer Tubing Diameter | 1/2" | n/a | 3/4" | 3/4" |
| Column or Filter Size | 100 cm diam column | ~4 m² replaced daily | 60 cm diam column | ~15 m² membrane |
| Vessel Volume | 50 L | 50 L | 2,000 L | 50 L |
1 Assumes 5 g mAb / L cell culture with ~3.5X concentration factor over first capture step.
Available Now
Find the PAK System that suits your current production rate and seamlessly scale your process with confidence.
Request quote